Hall Overview | Trade Fair Center Messe München

Graphic Halls

Download hall plan

Spaces / rooms Length in m Width in m Width in m Floor space m² Floor space m²
Spaces / rooms Halls A1 – A6 Length in m 161 Width in m 71 Floor space m² approx. 11,000
Spaces / rooms Halls B1 – B5 Length in m 161 Width in m 71 Floor space m² approx. 11,000
Spaces / rooms Hall B6 (High hall) Length in m 161 Width in m 71 Floor space m² approx. 11,000
Spaces / rooms Halls C1 – C6 Length in m 139 - 143 Width in m 71 Floor space m² approx. 10,000

The halls of Trade Fair Center Messe München set high standards in functionality, infrastructure and communications. Our 18 state-of-the-art halls at ground level offer you spacious areas with lots of natural light thanks to expansive glazing. All halls are fully vehicle-accessible due to the column-free construction and ceiling heights of 11 to 16 meters. Loading docks offer direct access to the exhibition halls, providing optimum conditions for loading and unloading exhibits. So exhibitors enjoy maximum flexibility during setup and dismantling.

Panoramic view of hall A6

Hall A6

Open thepanoramic view of Hall A6 in a new window.

Technical data

Halls A1 – A6
B1 – B5
Hall B6 (High Hall) Hall B6 (High Hall) C1 – C6 C1 – C6
Halls Length A1 – A6
161 m
Hall B6 (High Hall) 161 m C1 – C6 139 - 143 m
Halls Width A1 – A6
71 m
Hall B6 (High Hall) 71 m C1 – C6 71 m
Halls Total exhibition area A1 – A6
approx. 11,000 m²
Hall B6 (High Hall) approx. 11,000 m² C1 – C6 approx. 10,000 m²
Halls Clear height of longitudinal wall
(hall perimeter between entrances)
A1 – A6
approx. 5.70 m
Hall B6 (High Hall) approx. 7.80 m C1 – C6 approx. 5.70 m
Halls Clear height of hall girder supports
(hall sides)
A1 – A6
approx. 10.75 m
Hall B6 (High Hall) approx. 15.25 m C1 – C6 approx. 10.75 m
Halls Clear height of tie
(hall center)
A1 – A6
approx. 11.50 m
Hall B6 (High Hall) approx. 16.00 m C1 – C6 approx. 11.50 m
Halls Hall floor A1 – A6
Mastic asphalt
Hall B6 (High Hall) Mastic asphalt C1 – C6 Mastic asphalt
Halls Permissible distributed load A1 – A6
5 t/m²
(50 kN/m²)
Hall B6 (High Hall) 5 t/m²
(50 kN/m²)
C1 – C6 5 t/m²
(50 kN/m²)
Halls Permissible point load
(support area 0.3 m x 0.3 m, spacing approx. 1.5 m) does not apply to utility duct cover
A1 – A6
10 t
(100 kN)
Hall B6 (High Hall) 10 t
(100 kN)
C1 – C6 10 t
(100 kN)
Halls Permissible floor compression
under wheel and individual loads
A1 – A6
50 t/m²
(500 kN/m²)
Hall B6 (High Hall) 50 t/m²
(500 kN/m²)
C1 – C6 50 t/m²
(500 kN/m²)
Halls Permissible vertical load
at each suspension point
A1 – A6
100 kg
(1 kN)
Hall B6 (High Hall) 100 kg
(1 kN)
C1 – C6 100 kg
(1 kN)
Halls Entrance gates:
(Size) and [Number]

Vehicular access permitted

No vehicular access
A1 – A6



(4.5 m x 4.5 m) [6]

(2.5 m x 4.5 m) [4]
Hall B6 (High Hall)


(4.5 m x 4.5 m) [8]

(2.5 m x 4.5 m) [2]
C1 – C6


(4.5 m x 4.5 m) [6]

(2.5 m x 4.5 m) [4]
Halls Artificial illumination A1 – A6
100 Lux/m²
Hall B6 (High Hall) 100 Lux/m² C1 – C6 100 Lux/m²
Halls Ventilation A1 – A6
partly air-conditioned
Hall B6 (High Hall) partly air-conditioned C1 – C6 partly air-conditioned
Halls Utility supply ducts transverse to hall length, axes spaced at A1 – A6
5 m
Hall B6 (High Hall) 5 m C1 – C6 4.5 m (*)
Halls Width of utility ducts A1 – A6
0.35 m
Hall B6 (High Hall) 0.35 m C1 – C6 0.35 m
Halls Width of utility duct cover A1 – A6
0.43 m
Hall B6 (High Hall) 0.43 m C1 – C6 0.43 m
Utility connections
Halls A1 – A6
B1 – B5
Hall B6 (High Hall) Hall B6 (High Hall) C1 – C6 C1 – C6
Halls Water A1 – A6
DN 25/
min. 3.5 bar
Hall B6 (High Hall) DN 25/
min. 3.5 bar
C1 – C6 DN 25/
min. 3.5 bar
Halls Wastewater A1 – A6
DN 100
Hall B6 (High Hall) DN 100 C1 – C6 DN 100
Halls Sprinklers A1 – A6
DN 50
Hall B6 (High Hall) DN 50 C1 – C6 DN 50
Halls Compressed air A1 – A6
DN 50/
min. 10 bar
Hall B6 (High Hall) DN 50/
min. 10 bar
C1 – C6 DN 50/
min. 10 bar
Halls Gas
(availability depending on area coverage)
A1 – A6
DN 25/
20 mbar
Hall B6 (High Hall) DN 25/
20 mbar
C1 – C6 DN 25/
20 mbar
Halls Electricity supply A1 – A6
200 W/m²
Hall B6 (High Hall) 200 W/m² C1 – C6 200 W/m²
Telecommunications
Halls A1 – A6
B1 – B5
Hall B6 (High hall) Hall B6 (High hall) C1 – C6 C1 – C6
Halls User-neutral, wireline connections (phone, fax, analog, ISDN, DSL, LAN) A1 – A6
300
Hall B6 (High hall) 300 C1 – C6 300
Halls Wireless phone connections (DECT) A1 – A6
approx. 100
Hall B6 (High hall) approx. 100 C1 – C6 approx. 100
Halls Wideband connections (TV) A1 – A6
150
Hall B6 (High hall) 150 C1 – C6 150
Halls Fiber-optic connections
(Single-mode and/or gradient)
A1 – A6
150
Hall B6 (High hall) 150 C1 – C6 150