|
Halls
|
 |
 |
|
|
|
Fairgrounds map |
 |

- Fairgrounds map as PDF file for downloading
|
Technical specifications |
 |
Partial air-conditioning in the halls and enclosed entrances ensure
that all facilities are both functional and comfortable regardless of
the season or weather. Exhibitors throughout the grounds are supplied
with electricity, water and compressed air through a functional system
of floor/ground conduits. The most modern information technology for
transmitting data, voice and images as well as WLAN technology are
standard in all halls. Naturally, innovative communications technology
ensures optimum, high-speed connections between market partners at all
times. |
Description of halls and outdoor exhibition site |
 |
| 161 m |
161 m |
143 m |
139 m |
65 m |
| 71 m |
71 m |
71 m |
71 m |
54 m |
approx. 11,000 m² |
approx. 11,000 m² |
approx. 10,000 m² |
approx. 10,000 m² |
approx. 3,500 m² |
approx. 5.70 m |
approx. 7.80 m |
approx. 5.70 m |
approx. 5.70 m |
approx. 4.00 m (edge of hall) |
approx. 10.75 m |
approx. 15.25 m |
approx. 10.75 m |
approx. 10.75 m |
------- |
approx. 11.5 m |
approx. 16 m |
approx. 11.5 m |
approx. 11.5 m |
approx. 4.20 m (hall center) |
| Mastic asphalt |
Mastic asphalt |
Mastic asphalt |
Mastic asphalt |
Parquet |
| 5 t/m² (50 kN/m²) |
5 t/m² (50 kN/m²) |
5 t/m² (50 kN/m²) |
5 t/m² (50 kN/m²) |
2 t/m² (20 kN/m²) |
10t (100 kN) |
10t (100 kN) |
10t (100 kN) |
10t (100 kN) |
8t (80 kN) |
100 kg (1KN) |
100 kg (1KN) |
100 kg (1KN) |
100 kg (1KN) |
100 kg (1KN) |
|
(4.5 x 4.5m) [6] |
(4.5 x4.5m) [8]
|
(4.5 x 4.5m) [6]
|
(4.5 x 4.5m) [8]
|
------- |
(2.5 x 4.5m) [6] |
(2.5 x 4.5m) [2] |
(2.5 x 4.5m) [4] |
(2.5 x 4.5m) [2] |
(12.5x 4 m) [1] |
| 100 Lux/m² |
100 Lux/m² |
100 Lux/m² |
100 Lux/m² |
400 Lux/m² |
| Partially air-conditioned |
Partially air-conditioned |
Partially air-conditioned |
Partially air-conditioned |
Partially air-conditioned |
| 5 m |
5 m |
4.5 m (*) |
4.5 m |
4.85 m |
| 0.35 m |
0.35 m |
0.35 m |
0.35 m |
0.35 m |
| 0.43 m |
0.43 m |
0.43 m |
0.43 m |
0.43 m |
|
| diam. 25 / min. 3.5 bar |
diam. 25 / min. 3.5 bar |
diam. 25 / min. 3.5 bar |
diam. 25 / min. 3.5 bar |
diam. 25 / min. 3.5 bar |
| diam. 100 |
diam. 100 |
diam. 100 |
diam. 100 |
diam. 100 |
| diam. 50 |
diam. 50 |
diam. 50 |
diam.50 |
diam. 50 |
| diam. 50 / min. 10 bar |
diam. 50 / min. 10 bar |
diam. 50 / min. 10 bar |
diam. 50 / min. 10 bar |
diam. 50 / min. 10 bar |
| diam. 25 / 20 mbar |
diam. 25 / 20 mbar |
diam. 25 / 20 mbar |
diam. 25 / 20 mbar |
diam. 25 / 20 mbar |
| 200 W/m² |
200 W/m² |
200 W/m² |
200 W/m² |
200 W/m² |
|
| 300 |
300 |
300 |
300 |
100 |
| approx. 100 |
approx. 100 |
approx. 100 |
approx. 100 |
approx. 50 |
| 150 |
150 |
150 |
150 |
56 |
| 150 |
150 |
150 |
150 |
56 |
(*) Hall C1 also has two utility ducts that run parallel to the longitudinal walls. |
| 8 m / 12 m |
| Asphalt |
| Seeded gravel bed (grassed-over gravel-humus mixture, stony in parts) |
| 50t/m² (500kN/m²) |
| 30 Lux/m² |
|
| diam. 40 / 3.5 bar |
| DN100 |
| 50 W/m² |
|
| 1400 |
| approx. 200 |
| 100 |
| approx. 100 |
Separate technical guidelines apply to the foyer of the ICM. Floors – Permissible loads – Gates
General: With the exception of Hall B0, motor vehicles can be driven into the halls. However, doing so is only permissible at walking pace. The underfloor utility ducts can withstand the weight of a vehicle when covered. With an evenly distributed load, their load-bearing capacity corresponds to that of the general load-bearing capacity of the floor in question. The maximum point loads posted for the hall floors does not apply to the areas near the utility ducts.
The weight limits posted for the passenger and freight elevators may not be exceeded under any circumstances. Passenger elevators and escalators may not be used to transport freight.
Any damage caused by non-compliance with these guidelines must be remedied by MMG at the expense of the exhibitor and/or his agents.
|
- A description of the halls and the outdoor exhibition area can be download here: PDF file
|
Technical Guidelines |
 |
Our Technical Guidelines and General Terms of Participation (A) New Munich Trade Fair Centre can be downloaded here. |
|
|
|
|