Overview halls
Spaces/rooms Length in m Width in m Floor space m²
Halls A1 – A6 161 71 approx.11,000
Halls B1 – B5 161 71 approx.11,000
Hall B6
(High hall)
161 71 approx.11,000
Halls C1 – C3 143 71 approx.10,000
Hall C4 139 71 approx.10,000

The halls of Messe München set high standards in functionality, infrastructure and communication. Our 16 ultra-modern halls at ground level offer you spacious areas with ample natural light thanks to expansive glazing. All halls are fully vehicle-accessible due to the column-free construction and ceiling heights of 11 to 16 meters. Delivery zones directly adjacent to the exhibition halls provide optimum conditions for loading and unloading exhibits. So exhibitors enjoy maximum flexibility during set-up and dismantling.

Bitte installieren Sie Flash!/Please install Flash!


Hall A6

Open the panoramic view of hall A6 in a new window.

Technical data

Halls A1 - A6 B1 - B5 Hall B6
(High hall)
C1 - C3 C4
Length 161 m 161 m 143 m 139 m
Width 71 m 71 m 71 m 71 m
Total exhibition area approx. 11,000 m² approx. 11,000 m² approx. 10,000 m² approx. 10,000 m²
Clear height of longitudinal wall (hall perimeter between entrances) approx. 5.70 m approx. 7.80 m approx. 5.70 m approx. 5.70 m
Clear height of hall girder supports (hall sides) approx. 10.75 m approx. 15.25 m approx. 10.75 m approx. 10.75 m
Clear height of tie (hall center) approx. 11.50 m approx. 16.00 m approx. 11.50 m approx. 11.50 m
Hall floor Mastic asphalt Mastic asphalt Mastic asphalt Mastic asphalt
Permissible distributed load 5 t/m² (50 kN/m²) 5 t/m² (50 kN/m²) 5 t/m² (50 kN/m²) 5 t/m² (50 kN/m²)
Permissible point load (support area 0.3 m x 0.3 m, spacing approx. 1.5 m) does not apply to utility duct cover 10 t (100 kN) 10 t (100 kN) 10 t (100 kN) 10 t (100 kN)
Permissible floor compression under wheel and individual loads 50 t/m² (500 kN/m²) 50 t/m² (500 kN/m²) 50 t/m² (500 kN/m²) 50 t/m² (500 kN/m²)
Permissible vertical load at each suspension point 100 kg (1 kN) 100 kg (1 kN) 100 kg (1 kN) 100 kg (1 kN)
Entrance gates: (Size) and [Number]
Vehicular access permitted

No vehicular access


(4.5 m x 4.5 m) [6]

(2.5 m x 4.5 m) [4]


(4.5 m x 4.5 m) [8]

(2.5 m x 4.5 m) [2]


(4.5 m x 4.5 m) [6]

(2.5 m x 4.5 m) [4]


(4.5 m x 4.5 m) [8]

(2.5 m x 4.5 m) [2]
Artificial illumination 100 Lux/m² 100 Lux/m² 100 Lux/m² 100 Lux/m²
Ventilation partly air-conditioned partly air-conditioned partly air-conditioned partly air-conditioned
Utility supply ducts transverse to hall length, axes spaced at 5 m 5 m 4.5 m (*) 4.5 m
Width of utility ducts 0.35 m 0.35 m 0.35 m 0.35 m
Width of utility duct cover 0.43 m 0.43 m 0.43 m 0.43 m
Utility connections:        
Water DN 25/min. 3.5 bar DN 25/min. 3.5 bar DN 25/min. 3.5 bar DN 25/min. 3.5 bar
Wastewater DN 100 DN 100 DN 100 DN 100
Sprinklers DN 50 DN 50 DN 50 DN 50
Compressed air DN 50/min.10 bar DN 50/min.10 bar DN 50/min.10 bar DN 50/min.10 bar
Gas (availability depending on area coverage) DN 25/20 mbar DN 25/20 mbar DN 25/20 mbar DN 25/20 mbar
Electricity supply 200 W/m² 200 W/m² 200 W/m² 200 W/m²
Telecommunications:        
User-neutral, wireline connections (phone, fax, analog, ISDN, DSL, LAN) 300 300 300 300
Wireless phone connections (DECT) approx. 100 approx. 100 approx. 100 approx. 100
Wideband connections (TV) 150 150 150 150
Fiber-optic connections (Single-mode and/or gradient)

150


150


150


150
(*) Hall C1 also has two utility ducts along the longitudinal axis of the hall.